This problem arrived with LEDs. A filament bulb needs a real current to light up. An LED makes do with almost nothing, and a tiny current that used to go unnoticed is enough to make it glow. So the first thing to look at is what your bulb is doing exactly: a faint glow, a flicker, or normal light.
A glow that fades within seconds
Some LEDs take a few seconds to go out completely, while their electronics discharge. If the glow fades by itself, everything is normal.
A faint glow that stays: the possible causes
A switch with an indicator light
The little indicator light on the switch, the one that helps you find it in the dark, needs a bit of current, and that current flows through the bulb. A filament bulb didn't react to it. An LED can glow faintly from it, or flicker. It's usually enough to remove the indicator when it's removable, or to swap the switch for a model without one.
A smart switch or a dimmer
A smart switch fitted without a neutral wire has to let a trickle of current through the lamp to stay powered. Some dimmers do the same. With low-power LEDs, that's enough to make them glow. The fix is a small bypass module fitted near the lamp, which absorbs that current, or a control designed for LEDs. It's a subject we know well: see our home automation page.
Wires running side by side
When the wire to the lamp runs alongside a live wire for several metres, in the same conduit for example, it picks up a small voltage by induction. The long cables of a two-way switching circuit lend themselves to it. That voltage carries almost no energy: a filament bulb doesn't react, but a sensitive LED can glow. Another brand of bulb sometimes solves the problem. Otherwise, a bypass module does the job.
The switch cuts the neutral instead of the live
This is the cause not to leave as it is. A switch must cut the live wire, the one that brings the current. On an old or badly reworked installation, it sometimes cuts the neutral instead. The lamp goes off, or almost, but it stays connected to the live. The lamp holder is then still live, and changing the bulb is when you risk a shock. Only a measurement can confirm it, and the fix is to move the switching back onto the live.
The same thing happens with a lamp plugged into a socket, with a switch on its cord or a smart plug. If the plug can be turned round, try it the other way: if the glow disappears, the switch was cutting the neutral.
A bulb that really stays on
If the bulb is giving normal light, it's no longer an LED question.
Start by checking whether the lamp can be switched from two places. With two-way switching, the position of one switch means nothing: the other one may be turning it on.
Otherwise, the switch may be worn out, with welded contacts that no longer cut. It needs replacing. If the lamp is controlled by push buttons, it's an impulse relay or a timer in the panel doing the work: it may be stuck, or left in the forced-on position. And after building work, a wiring mistake can feed the lamp directly.
The right reflex, and a simple test
Until you know where the glow comes from, switch off the circuit's breaker before changing the bulb. The light switch alone isn't enough.
While you're at it, look at the lamp: once the breaker is off, it should go out completely. If it stays on, or keeps its glow, it's being fed by another circuit. Don't touch it again and call us.
You can also try a bulb of another brand, or a filament bulb if you still have one. If the glow disappears, it may have been an LED question. That doesn't prove the wiring is right, though.
What we do on site
We measure at the lamp holder and at the switch, to find out which wire is being cut and where the voltage comes from. Depending on the case, we move the switching back onto the live, change the switch, fit a bypass module or replace a control that isn't made for LEDs.
Our €132 incl. VAT call-out covers travel and the first half-hour, and replacing a switch usually fits within that time. If we can't find the fault, we don't charge for the call-out. The details are on our call-out prices page. For another lighting or socket fault, see our electrical repair page. And if you're changing your light fittings, our page on lighting installation explains how we go about it.
Request your free quote. Reply within 48h, detailed quote within a week.
Request a quote